Save Energy. Cut Costs. Light Better.
Outdated lighting drains your budget and reduces visibility where it matters most. Legacy Industries delivers end‑to‑end energy‑efficient lighting retrofits for offices, retail, healthcare, schools, warehouses, and industrial facilities across Upstate South Carolina, North Georgia, and Western North Carolina. We design, install, and commission modern LED systems—with smart controls—that improve safety, productivity, and aesthetics while lowering operating costs.
Why Retrofit Now?
| Benefit | What It Means |
|---|---|
| Energy Savings | LEDs use significantly less power than fluorescent, metal halide, and HPS—reducing utility bills immediately. |
| Lower Maintenance | Long lifespans mean fewer lamp changes, fewer lifts, and less downtime. |
| Improved Light Quality | Higher CRI and targeted CCT improve accuracy, comfort, and customer experience. |
| Controls & Automation | Occupancy sensors, daylight harvesting, and scheduling deliver additional savings. |
| Safety & Compliance | Proper light levels for egress and task areas; NEC‑compliant installs and clean inspections. |
What We Retrofit
| Existing Fixture | LED Retrofit/Replacement | Typical Result |
|---|---|---|
| T12/T8 Fluorescent Troffers | LED troffer kits or new low‑profile panels | Brighter, quieter (no ballast hum), lower wattage |
| High‑Bay Metal Halide (250–1000W) | LED high‑bay (UFO/linear) with optics | Faster start, higher efficacy, reduced maintenance |
| CFL/Incandescent Cans | LED downlights with dimming | Better color, cooler operation, controllable |
| Wall Packs/Floods | LED wall packs/floods with photocells | Improved perimeter visibility and security |
| Parking/Pole Lights | LED area lights with Type II/III/V optics | Uniform coverage; reduced dark spots and glare |
| Emergency/Exit | LED egress with battery backup | Code‑compliant egress and longer test cycles |
Service Options—From Quick Swaps to Full Redesigns
- One‑for‑One Retrofits: Fast conversion using retrofit kits or lamps where appropriate.
- Fixture Replacements: New fixtures for better optics, efficiency, and maintenance access.
- Lighting Redesign: Photometric modeling and layout changes to meet task/egress standards.
- Controls Integration: Standalone sensors or networked systems for zones, scheduling, and analytics.
- Exterior Upgrades: Poles, wall packs, and façade lighting with photocells and time scheduling.
- Emergency Systems: Exit and emergency lighting with monthly/annual test routines.
Design & Photometrics
We validate design decisions with photometric analysis so you see expected light levels before installation.
| Design Input | How We Use It |
|---|---|
| Task Type | Determine target illuminance (fc/lux) and uniformity |
| Mounting Height & Spacing | Select optics and form factor (troffer, linear, high‑bay) |
| Surface Reflectance | Adjust layout and CCT for visual comfort |
| Glare Control | Choose lenses/shields and dimming profiles |
| Code Requirements | Egress levels, sensor coverage, and emergency pathways |
Recommended CCT & CRI by Space
| Space Type | CCT | CRI | Notes |
|---|---|---|---|
| Open Office / Classrooms | 3500–4000K | 80+ | Neutral tones for focus and reduced eye strain |
| Retail / Showroom | 3000–3500K | 90+ | Enhanced color rendering for merchandise |
| Warehousing / Production | 4000–5000K | 80+ | Crisp visibility, high‑bay optics to cut shadows |
| Healthcare / Labs | 3500–4000K | 90+ | Accurate color, low glare, quiet drivers |
| Exterior / Security | 4000–5000K | 80+ | Camera‑friendly, improved recognition |
Controls That Multiply Savings
| Control | Use Case | Outcome |
|---|---|---|
| Occupancy/Vacancy Sensors | Offices, restrooms, storage | Lights off when empty; automatic savings |
| Daylight Harvesting | Windowed perimeters, skylights | Dimming based on natural light |
| Time Scheduling | Warehouses, signage, exteriors | Predictable on/off, reduced manual errors |
| Multi‑Scene Dimming | Conference rooms, classrooms | Pre‑set scenes for presentations and tasks |
| Centralized Control | Multi‑floor facilities | Building‑wide control and monitoring |
Our Retrofit Process
- Site Walk & AuditInventory fixtures, mounting heights, and controls; note safety and code items.
- Design & ProposalProvide photometrics, fixture/driver specs, control strategy, and ROI summary.
- Scheduling & LogisticsPhase work by area/shift to minimize disruption; plan lifts and safety zones.
- InstallationCertified electricians remove legacy gear, install new fixtures/controls, and label circuits.
- CommissioningProgram sensors, set schedules, test emergency paths, and verify light levels.
- CloseoutDeliver as‑builts, control maps, fixture schedules, and warranty records.
Warehouses & Industrial—High‑Bay Done Right
- Linear/UFO High‑Bays with aisle optics to push light to work surfaces
- Motion Zoning by aisle for safe, efficient operation
- Daylight Zones under skylights to cut daytime usage
- Low‑Glare Lenses to reduce eye fatigue and improve scanning/QA
Offices, Education & Healthcare
- Low‑profile troffers and panels for clean ceilings
- Flicker‑free drivers for comfort and camera friendliness
- Scene controls in conference/training rooms
- Tunable‑white options where circadian support is desired
Retail & Customer‑Facing Spaces
- High‑CRI accents for merchandise and branding
- Adjustable track/linear accents with tight beam options
- Façade and signage lighting for visibility and foot traffic
- Warm/neutral palettes to match finishes and mood
Exterior, Security & Parking
- Area lights with Type II/III/V optics for uniform coverage
- Wall packs and floods with photocells/motion
- Canopy and entry lighting for customer/employee safety
- Dark‑sky‑friendly options to reduce glare and spill
Energy & Cost Outcomes
| Measure | Typical Impact |
|---|---|
| Wattage Reduction | 40–70% vs. legacy fixtures |
| Maintenance Calls | Reduced by 50–80% with long‑life LEDs |
| Cooling Load | Lower heat adds HVAC savings in conditioned spaces |
| Payback Window | Often 1–3 years depending on runtime and utility rates |
(Impacts vary by facility; we provide project‑specific projections.)
Quality & Safety Standards
We install to NEC and local code, using UL‑listed fixtures and drivers. Our crews maintain clean sites, safe barricades, and lift protocols. Emergency and egress paths are validated and documented. We label panels and zones for easy maintenance and future changes.
Maintenance & Support
- Lens cleaning and light‑level checks
- Driver/board replacement as needed
- Sensor recalibration and schedule updates
- Warranty tracking and service logs
- Optional annual inspections for multi‑site portfolios
Service Areas
Lighting retrofits available throughout:
- Greenville
- Spartanburg
- Anderson
- Simpsonville
- Laurens
- Gaffney
- Western North Carolina
- North Georgia
We coordinate work around business hours to keep operations moving.
Frequently Asked Questions
Will my space be too bright or too dim after retrofit?
We design with photometrics and field verify using light‑level targets appropriate to your tasks.
Do LEDs work with my existing dimmers?
Sometimes. We match drivers and controls to ensure smooth, flicker‑free dimming.
Can you retrofit without shutting down operations?
Yes. We phase work, schedule off‑hours, and maintain safe egress at all times.
What about rebate or incentive paperwork?
If available in your area, we can provide documentation your program requires.
How long do LED fixtures last?
Commercial‑grade LEDs offer long life; actual results depend on runtime, heat, and driver quality. We specify proven fixtures to maximize lifespan.
Illuminate Smarter with Legacy Industries
When you upgrade lighting, you upgrade how your building works. Legacy Industries helps you choose the right fixtures, controls, and layout to reduce costs and elevate the user experience—today and for years to come. From the first audit to final commissioning, we deliver a clean, code‑compliant retrofit that looks better, performs better, and pays you back in savings.
Phone: (864) 431‑4670
Email: tyler.abbott@legacyind.net
Service Region: Upstate South Carolina and surrounding areas